$1,415.00 – $1,720.00
Designed specifically for testing live or dead spout applications from 240V up to 33kV. The Modiewark AC Non–Contact Spout tester can be used on inside applications up to 33kV on metal clad switch gear.
This Kit is a non-contact voltage tester for detecting electromagnetic and AC electrical voltage sources.
This kit is designed to be used above 600 volts.
This Kit can be supplied with an Electrical certificate (Certificate is for Stick and Spout).
Goto the ACCESSORIES tab at the top of the page to order more attachments and gloves.
Goto MODEL Tab Below for Voltage selection.
The Spout 1 Kit Includes:
The Modiewark spout tester is used specifically for the testing of live or dead spout applications up to 33kv. The Modiewark spout tester can be configured with, any voltage range required starting with 240 volts and ending in 33kv. The spout tester length can be configured for any purpose that is required; information on this can be obtained from our sales staff.
The Modiewark non-contact voltage tester can be manufactured with a selection of voltages ranging from 110/240 volts to 750 kilovolts.
We provide a selection of common voltages in our standard range shown below. Custom voltages ranges can be provided per customer’s request through consultation with our helpful sales staff.
Voltage levels stated are between phase voltages. Voltages displayed in bold are URD test point settings.
If you would like to Purchase an Australian model, select from our range below to go to our shopping cart.
Model | Selectable Voltages |
---|---|
Model | Selectable Voltages |
S4A | OFF, 240V, 2kV, 6.6kV |
S4B | OFF, 240V, 2kV, 6.6kV, 11kV |
S4C | OFF, 240V, 2kV, 5kV, 11kV |
AIS | OFF, 240V, 1kV, 6.6kV, 33kV |
VR | OFF, 240V, 2.2kV, 6.6kV, 11kV, 22kV |
SECV | OFF, 240V, 6.6kV, 11kV, 22kV, 66kV |
MWB | OFF, 240V, 3.3kV, 6.6kV, 11kV, 22kV, 33kV |
RTC | OFF, 240V, 5kV, 6.6kV, 11kV, 12.7kV, 22kV, 33kV |
S9 | OFF, 240v, 2kV, 11kV, 22kV, 33kV, 66kV, 132kV, 330kV |
S9SA | OFF, 240V, 2kV, 6kV, 11kV, 22kV, 33kV, 132kV, 275kV |
CSA | OFF, 240V, 4.2kV, 15kV, 25kV, 35kV, 69kV115kV, 230kV |
NZ | OFF, 240V, 2kV, 11kV, 22kV, 33kV, 66kV, 110kV, 220kV |
SEAQ | OFF, 240V, 3.3kV, 6.6kV, 11kV, 33kV, 66kV, 110kV, 275kV |
ETSA | OFF, 240V, 3.3kV, 7.6kV, 11kV, 33kV, 66kV, 132kV, 275kV |
NM | OFF, 240V, 1kV, 3.3kV6.6kV, 11kV, 22kV, 33kV |
NRCC | OFF, 240V, 1kV, 3.3kV, 6.6kV, 11kV, 33kV, 66KV, 132kV |
WA1 | OFF, 240V, 3.3kV, 6.6kV, 11kV, 22kV, 33kV, 66kV, 132kV |
S7 | OFF, 240V, 2kV, 11kV, 22kV, 33kV, 66kV |
S7A | OFF, 240V, 11kV, 33kV, 66kV, 132kV, 330kV |
CIG | OFF, 240V, 415kV, 3.3kV, 6.6kV, 11kV, 22kV, 33kV, 66kV |
ABC | OFF, 240V, 11kV, 33kV, 66kV, 132kV |
VRS | OFF, 240V, 1kV, 2.2kV, 6.6kV, 11 kV, 22kV |
HEC | OFF, 240V, 6.6kV, 11 kV, 22kV, 44kV, 88kV, 110kV, 220kV |
WRA | OFF, 240V, 4.2kV, 15kV, 25KV, 35kV, 48kV, 69kV, 15kV, 25kV, 35kV |
RTC | OFF, 240V, 5kV, 6.6kV, 11KV, 12.7kV, 22kV, 33kV |
VRS | OFF, 240V, 1kV, 2.2kV, 6.6KV, 11kV, 22kV |
S10A | OFF, 240V, BATT, 4.8kV, 7.2KV, 16kV, 2.4/4.2kV, 4.8/8.3kV, 8.0/13.8//7.2/12.5kV , 14.4/25//16/27.6kV, 44kV, 69kv |
S11A | OFF, 240V, 2.4/4.2kV, 4.8/8.3kV, 7.2/12.5KV, 8/13.8kV, 14.4/25kV, 16/27.9kV, 44kV, 69kV, 115kv, 500kv |
CUSTOM | Choose your own voltage combinations |
These Modiewark models shown above are for Australian power lines. For more Information on American models please visit SailsburybyHoneywell.com
Since the 1960’s, this iconic device is widely regarded as the best non-contact tester for AC power on the market today. It set the international standard for non-contact voltage testing. Whether conducting maintenance, repairs or responding to a high voltage emergency, you need the Modiewark AC Non-contact Tester.
Designed for all industries that use AC electricity, the Modiewark AC comes in an array of voltage settings for any environment… from 50 to over a million volts.
The Modiewark has been used by industry professionals since the early 70’s for live or dead voltage determination of overhead power lines and underground power at URD test points.
The Modiewark AC has two main functions, firstly as a proximity device to determine live or dead situations and then as a touch device to verify the tester has physically reached the AC field around designated mains under test.
The unique nature of the sensor plate within the unit allows for directional checks such as checking low voltage when high voltage is nearby. Induced voltages on isolated conductors are checked by increasing the Modiewark’s sensitivity.
The Modiewark AC is a must have when:
The Modiewark is a non-contact voltage tester which detects the presence of an alternating electric or electromagnetic field as both a proximity and touch device.
Its unique switching action allows for the identification of alternating currents at a distance between 200 mm and 300 mm from a voltage source from 110 volts to 750,000 volts.
The Modiewark has been used by industry professionals since the early 70’s for live or dead voltage determination of overhead power lines and underground power at the URD test point. Firstly as a proximity device to determine live or dead situations and then as a touch device to verify the tester has physically reached the AC field around designated mains under test.
The Modiewark can also be used indoors on the 240/110 volt setting, tracing voltage sources from power distribution boards and cable fault detection.
The unique nature of the sensor plate within the unit allows for directional checks such as checking low voltage when high voltage is nearby. Induced voltages on isolated conductors are checked by increasing the Modiewarks sensitivity.
Radiated field strength increases with voltage and decreases with earth shielding. The radiated field from a cable of closely bunched conductors supplied by three phase power tends to cancel. Detecting distance of a 240 volt single live wire is approximately 100mm and with a bunched neutral and earth, as a flexible cable, the distance is 50mm.
The Modiewark casing and handle are designed to channel a flashover around the internal circuit and into the battery housing. Please note any damage to the head of the Modiewark will result in failure the unit must be taken out of service and repaired.
The Modiewark tester can now be fitted with moisture and dust proof fittings for harsh environments and provides an IP63 rating.
The standard Modiewark is supplied with a sunrise (universal) fitting to allow the attachment of an insulation extension stick (hot stick) for all high voltage applications. A standard or plain handle can be requested without this fitting.
The Modiewark is available with and without a self test function. This continuous self checking of the Modiewark non-contact voltage tester provides an essential safety feature that:
Please note that all Australian models must be sold with the self test function.
The batteries are placed in the handle with the positive side to the top. A battery strap is placed into the handle coil end first. When the batteries are placed in the handle shake to allow the battery strap to fall into the correct position.
Screw the handle with batteries inside to the head unit, with a firm twist in a clock-wise direction.
A Modiewark can be fitted with wings or depth limiters, these limiters allow the unit from entering restricted compartments and allow constant depth readings over many tests over time.
If using an insulation stick, place the unit onto the stick using the sunrise (universal) fitting or the bayonet adaptor fitting.
If using handheld, hold the Modiewark unit by the handle below the sunrise fitting.
Note: The spout tester will not activate if the spout is disconnected preventing the unit being used without a sensor plate.
There are standard models available in spout testers, SP-150, SP-200, SP-250, SP-300, SP-400. All available with or without depth limiters. The spout tester length can be configured for any purpose that is required; information on this can be obtained from our sales staff.
The Spout heads can be configured to any length up to 400 mm and as short as 50 mm. The diameters of the head of the spout can vary to fit the application. Minimum diameter 20mm, Maximum test voltage off 11kV or 46 mm diameter maximum test voltage of 33kV.
A high Voltage Spout is available. This Spout is 400mm Long and 45 mm dia the tested breakdown voltage is 100,000 volts.
Each Spout Tester has certification for the first 12 months. Re-testing is available on return of the tester and spout.
A Modiewark can be fitted with wings or depth limiters, these limiters allow the unit from entering restricted compartments and allow constant depth readings over many tests over time.
The Modiewark hand shield provides additional flash or arc protection as well as accidental movements of the operator.
Send through an enquiry and an experienced Modiewark team member will get back to you ASAP.