Meter Reader Test Results

Voltage vs. Measurement Results

Voltage at test point
(Volts)
Sensitivity High
(Metres)
Sensitivity Low
(Metres)
250 2.5 2.1
240 2.4 1.9
220 1.7 1.8
200 1.3 1.2
180 1 0.9
160 0.8 0.8
140 0.6 0.6
120 0.5 0.5
100 0.45 0.45
80 0.3 0.3
60 0.1 0.01
40 0.1 0.01
20 0.1 0.01
10 0.1 0.01

These Meter Reader test results reflect Low voltage detector unit approaching on an energised metal enclosure.